Chapter 2 Using Automated Libraries and Manually Loaded Drives 25
4. Use the samcmd(1M) on command to turn on the automated library and the drive.
Issue this command once for the drive and once for the library.
For eq, specify the equipment ordinal of the library or drive as defined in the mcf
file.
If the automated library performs an audit when it is turned on, you are done.
5. Follow these steps if the automated library does not perform an audit when it is
turned on:
a. Put the cartridge back into its storage slot.
b. Use the chmed(1M) command to adjust the library catalog to set the occupied
flag for the damaged tape.
Use this command in the following format:
For more information about the chmed(1M) command, see the chmed(1M) man
page.
If you keep the cartridge out, and you want to put it back in later, you must import
the cartridge into the automated library.
Catalog Operations, Importing Cartridges, and
Exporting Cartridges
The physical addition (import) of cartridges to and removal (export) of cartridges
from an automated library enables you to perform several functions, including the
following:
Replace cartridges.
samcmd on eq
chmed +o eq:slot
TABLE 2-8 Arguments for chmed(1M)
Argument Meaning
eq The equipment ordinal of the automated library or drive as defined in the mcf
file.
slot The number of the storage slot in the library as recognized in the library
catalog. This argument is not applicable for manually loaded drives.